ENERGY RECOVERY NUMBERS
Electricity produced in electric mode only | 350,000 megawatt-hours |
Thermal energy produced in cogeneration mode | 170,000 megawatt-hours |
Electricity produced in cogeneration mode | 320,000 megawatt-hours |
Fuel saved per year | 70.000 TOE |
PLANT PROFILE
Lines number | 3 (identical) |
Calorific value of the waste (CV) | 11.000 kJ/kg |
Calorific value range | min 6.000/max 16.000 kJ/kg |
Total nominal thermal power | 206 MWt |
Total steam production | 220 t/h |
Steam pressure | 60 bar (a) |
Steam temperature | 420° C |
Line capacity for each of the 3 flues | 127.000 Nm3/h |
Flue gas temperature released from the chimney | 120°C |